What was found
DURING SCHEDULED C-9 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND LH CHINE ANGLE FITTING CRACKED THOUGHT BOLT HOLE AT FS245, LBL61, WL141-143. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 0844. / PSE# 53-40-11, AD 2012-06-09