What was found
DURING SCHEDULED B-1 CHECK WHILE PERFORMING OTHER MAINTENANCE, FOUND LH SLOPING LONGERON LOWER END FITTING CORRODED AT FS737, LBL61, WL140. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 0120. / PSE#53-50-12, AD 2012-06-09