What was found
DURING SCHEDULED B-3 CHECK UNDER JOB CARD HB5302, FOUND CENTER OVERHEAD EMERGENCY EXIT DOOR FORMER CORRODED AT FS637-657, BL0-LBL20, WL285. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 1001224122.