What was found
EXFOILATION CORROSION STA 258 RT CHINE, INSPECTED DAMAGED AREA PER ENGINEERING IN DIRECTIVE EDF07-1 STEP 1 AND STEP 2 DAMAGE WITHIN PERMISABLE LIMITS PER STEP 2 OK FOR INTENDED FERRY FLT RT CHINE ANGLE, FS 257, BLR 61, WL 146, (P/N 372322-1). REPAIRED IAW SMP 583 FIG 53-40-26 PG 69. RT RING SEGMENTS (2 EA) FS 250 AND FS 260, BLR 61, WL 146, (P/N 371653-39). REPAIRED IAW SMP 583 FIG 51-140-21 PG 60. RT TIE FITTING FS 245 TO 251, BLR 61, WL 146 (P/N 373838-4). REPLACED IAW SMP 583 CHP 51-10 PG 5. RT END FITTING FS 245, BLR 61, WL 146 (P/N 373188-1). REPLACED IAW SMP 583 CH 51-10 PG 5.