What was found
DURING C-CHECK/BRIDGING INSPECTION, A CRACK AT WEB CTR FUS, FS 597.0 TO 617.0, BL 61.625 UPPER, EXTENDING FROM ONE WIRE BUNDLE CUTOUT HOLE TO ANOTHER, APPROXIMATELY 1 INCH LENGTH AND AN ADDITIONAL CRACK WHICH HAS EXTENDED JUST PAST A CREW HOLE ABOVE THE 1 INCH CRACK. THE WEB WAS REPLACED WITH A CHANNEL STIFFENER INSTALLED IN THE CENTER OF THE WEB.