What was found
DURING SCHEDULED C1 INSPECTION PER HST5319 (ST-19) FOUND FS 597 RT MLG BEAM CORRODED AT WL 146. REMOVED CORROSION, TREATED AND REPAIRED IAW SRM 583 53-40-31. DRC-0020-SM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C1 INSPECTION PER HST5319 (ST-19) FOUND FS 597 RT MLG BEAM CORRODED AT WL 146. REMOVED CORROSION, TREATED AND REPAIRED IAW SRM 583 53-40-31. DRC-0020-SM.