What was found
DURING SCHEDULED C1 INSPECTION PER HST5409 FOUND NR 3 I/B TRUSS MONT LOWER ATTACHMENT BARREL NUT CAVITY CRACKED. REPLACED TRUSS MOUNT IAW SRM 583-54-30-06. (P/N 360015-19) INSTALLED. DRC-0009 AND 0138-SM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C1 INSPECTION PER HST5409 FOUND NR 3 I/B TRUSS MONT LOWER ATTACHMENT BARREL NUT CAVITY CRACKED. REPLACED TRUSS MOUNT IAW SRM 583-54-30-06. (P/N 360015-19) INSTALLED. DRC-0009 AND 0138-SM.