As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HNL - DURING 'EXTERIOR LIGHT CHECKS, THE RIGHT FORWARD EXTERIOR EMERGENCY FLOOD LIGHT DID NOT ILLUMINATE WITHOUT AIRCRAFT POWER. IT WAS DETERMINED THE ORIGINAL 'FACTORY INSTALLED' POWER SUPPLY UNIT WAS OF THE WRONG PART NUMBER. REPLACED EMERGENCY POWER SUPPLY UNIT (FIN10WL) WITH SERVICEABLE EMERGENCY SUPPLY POWER UNIT IAW JIC 33-51-21-RAI-10000-002. OPERATIONALLY CHECKS GOOD JIC 33-50-00-OPT-10000-001. PART TOTAL CYCLES, 9 HOURS. (X)