Service difficulty report · Potentiometer · Urocop EC130B4

Difficulty date
May 12, 2008
Submitted
July 17, 2008
Operation
Air carrier
Aircraft
N806MH
Make and model
Urocop EC130B4
Aircraft serial
3833
Engine
Tmeca ARRIEL2B1
Part
Potentiometer
Part number
116SF2C502W253
Condition
Failed
Part time
385 hours
Component
Ecds
Component part number
EC130B4
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

A FAULT CODE WAS GENERATED ON SHUTDOWN INDICATING A DEFECT OF COLLECTIVE POTENTIOMETER. A NEW PART WAS INSTALLED, NO FURTHER FAULT WAS DETECTED. THIS IS RECURRING FAILURE FOR THIS PART WHICH HAS EFFECTED DISPATCH RELIABILITY FOR THIS MODEL HELICOPTER. SUGGEST AN ALTERATION OF FAULT SENSING SOFTWARE TO REDUCE FAULT SENSITIVITY TO PERHAPS A SIGNAL LOSS OF 0.5 SECOND RATHER THAN 1/20TH OF A SECOND. AN OPTIC RATHER THAN A RESISTANCE BASED SENSOR SHOULD BE CONSIDERED AS CONTACT POINT IS DAMAGED BY AC VIBRATION WHEN AC POWER SETTINGS ARE SET FOR CRUISE FLIGHT. (K)