Service difficulty report · Potentiometer · Urocop EC130B4

Difficulty date
October 10, 2007
Submitted
August 5, 2008
Operation
Air carrier
Aircraft
N805MH
Make and model
Urocop EC130B4
Aircraft serial
3799
Engine
Tmeca ARRIEL2B1
Part
Potentiometer
Part number
116SF2C502W253
Condition
Failed
Location
Collective
Part time
428 hours
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

A FAULT CODE WAS GENERATED AT ENGINE SHUTDOWN INDICATING A DEFECT WITH THE COLLECTIVE POTENTIOMETER. A NEW POTENTIOMETER WAS INSTALLED. THIS HAS BECOME A VERY COMMON PROBLEM WITH THE LATEST REPLACEMENT PART THAT THEY LAST MUCH LESS THAN THE 2000 HOUR SERVICE LIFE LIMIT. THE SAME POTENTIOMETERS ORIGINALLY INSTALLED LASTED AS LONG AS 4000 HOURS WITHOUT FAILING. SHORTLY AFT THE REQUIREMENT TO REPLACE THESE PART AT A 2000 HOUR INTERVAL IT SEEMS THAT THE QUALITY OF THESE PARTS DRAMATICALLY DECREASED. ENGINE ANTICIPATOR CONTROL CIRCUIT SIGNAL OF COLLECTIVE POSITION IS GENERATED BY THIS POTENTIOMETER TO CONTROL DECU SIGNAL TO THE ENGINE. (K)

More about the Urocop EC 130 B4