Service difficulty report · Hmu · Urocop EC130B4

Difficulty date
July 19, 2011
Submitted
July 21, 2011
Operation
Air carrier
Aircraft
N851MH
Make and model
Urocop EC130B4
Aircraft serial
4340
Aircraft time
3,724 hours, 7,533 cycles
Engine
Tmeca ARRIEL2B1
Engine time
5,684 hours, 10,124 cycles
Part
Hmu
Condition
Failed
Location
Engine
Part time
2,824 hours
Stage of operation
CR
How discovered
O
Nature of condition
R, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ACFT EXPERIENCED A FORCED LANDING. ON THE FIRST SCHEDULED STRIP TOUR AT DUSK, THE PILOT SUDDENLY NOTED SOME UNUSUAL MODERATE LATERAL VIBRATIONS IN THE AIRFRAME. PILOT IMMEDIATELY DIVERTED BACK TO THE AIRPORT AND JUST SHORT OF FLARING THE ACFT INTO THE HOVER/TAXI FLIGHT MODE, HAD BOTH RED AND AMBER GOVERNOR LIGHTS ILLUMINATE ON THE CAUTION WARNING PANEL. PILOT EXECUTED AN IMMEDIATE AND UNEVENTFUL RUN ON LANDING. ACFT TOWED TO THE HANGER. PILOT DID INDICATE THAT THE ENGINE NG SPEED WAS FLUCTUATING DURING RETURN, BUT WAS UNSURE IF THAT WAS THE CAUSE OR THE EFFECT OF THE AIRFRAME LATERAL VIBRATIONS. FAILURE CODE INDICATED ON THE VEMD WAS CODE 129 INDICATING A STEPPER MOTOR OR RESOLVER FAILURE. FROM PREVIOUS INCIDENTS WHERE NG INSTABILITY WAS NOTED, SUSPECT HMU, WHICH WAS OF OLDER STYLE DIAPHRAGM, WAS EXPERIENCING A PARTIAL DIAPHRAGM RUPTURE. HMU HAS BEEN RETURNED TO THE MFG FOR EVALUATION AND REPAIR. EXAMINATION OF THE ACFT REVEALED NO DAMAGE AND SUBSEQUENT TO HMU REPLACEMENT AND A NORMAL CHECK FLIGHT RESULT THE ACFT HAS BEEN RETURNED TO SERVICE.

More about the Urocop EC 130 B4