SDR MAC020802

Service difficulty report · Metering Valve · Aerosp ATR72202

Difficulty date
February 3, 2008
Submitted
February 15, 2008
Operation
Air carrier
Aircraft
N810FX
Make and model
Aerosp ATR72202
Aircraft serial
220
Aircraft time
25,321 hours, 26,796 cycles
Part
Metering Valve
Part number
20125112Y00
Part serial
107
Condition
Malfunctioned
Location
Brake System
Stage of operation
TX
How discovered
C
Nature of condition
O
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING TAXI ON INITIAL BRAKE CHECK, LOW RIGHT BRAKE PRESSURE WAS DISCOVERED ON BOTH THE PIC AND SIC SIDES. THE A/C RETURNED TO THE GATE. THE BRAKE METERING VALVE WAS REPLACED.