Service difficulty report · Controller · Saab 340B

Difficulty date
August 25, 2008
Submitted
September 15, 2008
Operation
Air carrier
Aircraft
N442XJ
Make and model
Saab 340B
Aircraft serial
340B442
Aircraft time
23,255 hours, 25,517 cycles
Part
Controller
Condition
Inoperative
Location
Cabin Temp
Stage of operation
CL
How discovered
O
Nature of condition
B
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RT HAND DUCT OVERTEMP ILLUMINATED AFTER TAKEOFF. RT BLEED AUTOMATICALLY CLOSED. FLIGHT ATTENDANT REPORTED SEEING SMOKE AND EXTREME HEAT IN THE CABIN. RETURNED TO LAND AT MEMPHIS AFTER DECLARING EMERGENCY. CND RT DUCT OVERTEMP. FOUND FLIGHT DECK TEMP SENSOR BLOWER INOP AND CABIN AUTO TEMP INOP. R&R CABIN AUTO TEMP CONTROLLER AND F DECK TEMP SENSOR. ALL CHECKS GOOD IAW SF340 AMM CHP. 21-60-00-05. TEMP SENSOR P/N ON & OFF BYLF51175 IAW 21-61-15-04. TEMP CONTROLLER P/N ON & OFF 754661-8, S/N ON 98022638, S/N OFF 96121815.