What was found
DURING C-CHECK, FOUND 3 & 4 RIBS CRACKED AT ENDS OF LEADING EDGE STA 611 BR. MX FABRICATED NEW ANGLES AND SHIMS IAW 57-10-30, HOLES TRANSFERRED FROM EXISTING HOLES AND IAW SRM 57-10-30. CUT BACK 3 SUPPORT RIBS WITH CRACKS IN REF TO SRM 57-10-30, FNDT REQUIRED TO VERIFY REMOVAL OF CRACKS. ALODINED AND PRIMED ANGLES AND SHIMS IAW SRM 51-20-42/43, WET INSTALLED RIVETS AND FAY SEALED ANGLES AND SHIMS IAW SRM 51-20-50. TOP COAT EFFECTED AREA ON EXTERIOR SURFACE IAW SRM 51-20-43.