What was found
RUNAWAY TRIM-FO WAS HAND FLYING AC. AFTER CYCLING A/P MASTER THE PROBLEM WENT AWAY. MAINTENANCE PERFORMED RTS TESTS ON PITCH TRIM AND ELEVATOR SYSTEMS. ALL CHECKS GOOD IAW RJ-85MM CHAP 22. CND ON GROUND PITCH TRIM ALL CHECKS GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RUNAWAY TRIM-FO WAS HAND FLYING AC. AFTER CYCLING A/P MASTER THE PROBLEM WENT AWAY. MAINTENANCE PERFORMED RTS TESTS ON PITCH TRIM AND ELEVATOR SYSTEMS. ALL CHECKS GOOD IAW RJ-85MM CHAP 22. CND ON GROUND PITCH TRIM ALL CHECKS GOOD.