What was found
FOUND DURING C-CHECK DENTS ON RT FUSELAGE AFT OF RADOME, MAINTENANCE FABRICATED DOUBLER 2024T-3 032, LAYOUT AND DRILLED FASTENER PATTERN, ALODINE, PRIMED AND TOPCOATED DOUBLER FAY SEALED, INSTALLED AND FILLET SEALED IAW SAAB STATEMENT 72SDS2312, PAINTED REPAIR RT FUSELAGE AFT OF RADOME IAW SRM 51-20-43.