What was found
FOUND DURING C-CHECK, DENTS ON RT UPPER HORIZONTAL STABILIZER BETWEEN STATIONS HS 75.90 AND HS 99:13. MAINTENANCE MEASURED DENTS AND FOUND MOST O/B DENTS TO FALL WITHIN AREA LIMITS .023 DEEP & DIA OF .734. I/B 2 DENTS ARE OUT OF LIMITS BEING LESS THAN 4X THERE LENGTH APART DENTS ARE 3.25 INCHES APART WITH 1 INCH DENT AT .026 DEEP. INSTALLED PATCH ON 2IB DENTS ON RT UPPER HORIZONTAL STAB IAW SRM 55-10-10.