What was found
FOUND DURING C-CHECK, FLOOR BOX ASSEMBLY NR 171DZ PUNCTURED. MAINTENANCE REPAIRED PUNCTURE AND COMPOSITE DAMAGE PER WETLAY UP REF SAAB SRM 51-70-50. REINFORCED BOX ASSY WITH FIBRELAM GRADE 11, AND BONDEDIN PLACE USED REDUX 252, REF SAAB SRM 51-33-00, AND REF TO SAAB STATEMENT 72LCS0689 FOR USE OF FIBRELAM GRADE 11.