What was found
FOUND DURING C-CHECK, SEVERAL DENTS IN RT FUSELAGE ABOVE AND BELOW PREVIOUS REPAIR AT STA 339.0. REFER TO CELSIUS TASK CARD 2528, W/O 18843. MAINTENANCE FOUND DENTS OUT OF ALLOWABLE LIMIT REF SAAB SRM 51-10-10 LESS THAN 4L. NDT PERF FVNDT006 EDDY CURRENT, NO CRACKS NOTED. FOR CORRECTIVE ACTION AND DETAIL OF REPAIRS SEE IPM 12 FORM. PRESSURIZED A/C AS PER 21-00-00, OPS CHECK GOOD.