What was found
FOUND DURING C-CHECK, LT FUSELAGE HAS SEVERAL DENTS AT STA 350.0 REFER TO CELSIUS TASK CARD 2531, W/O 18843. MAINTENANCE FOUND DENTS OUT OF ALLOWABLE LIMIT REF SAAB SRM 51-10-10 LESS THAN 4L. FABRICATED REPAIR DOUBLER / TRIPLER PER PRINCIPLES OF SRM 53-70-10, ALODINED, PRIMED AND TOPCOATED REPAIR PA RTS PER SRM 51-20-42/43. NDT PERF FVNDT006 EDDY CURRENT, NO CRACKS NOTED. FOR CORRECTIVE ACTION AND DETAIL OF REPAIR SEE IPM 12 FORM.