What was found
FOUND DURING C-CHECK, 3 RIBS CRACKED ON LEADING EDGE PANEL 611BR. REFER TO CELSIUS TASK CARD 6506, W/O18843. MAINTENANCE REMOVED CRACKED SECTION OF 3 CRACKED RIBS IAW SRM 57-10-30. NDT PERF FVNDT006EC NO CRACKS NOTED. FABRICATED 3 REPAIR ANGLES AND SHIMS IAW SRM 57-10-30. TREATED AND PRIMED RIBS AND REPAIR ANGLES IAW SRM 51-21-17/28, INSTALLED 3 REPAIR ANGLES WET IAW SRM 51-40-21. FOR PAINT TOUCH UP SEE WO 18843, TASK 2518 IPM12 FORM 007.