What was found
FOUND DURING C-CHECK, CORROSION AT AIRSTAIRS TRACK BETWEEN STA 258 - STA 288 AT LBL 27, REFER TO CELSIUS TASK CARD 1538, W/O 18737 AND SAAB STATEMENT 340SDS000199. MAINTENANCE REMOVED CORROSION AS REQUIRED, IAW SRM 51-70-40. REMAINING MATERIAL IS OUT OF LIMITS REF: SRM 51-10-10. ALODINED, PRIMED AND TOPCOATED REF SRM 51-20-42/43. MATERIAL LOSS IS ACCEPTABLE AS IS IAW SAAB EO 340SDS000199.