What was found
FOUND DURING C-CHECK, CORROSION ON FLOOR BOARD FLANGE AT LBL 18.30 FROM STA 294 TO STA 411.9 REFER TO CELSIUS W/O 18955 TASK CARD 1545 AND SAAB STATEMENT 340SDS000376. MAINTENANCE REMOVED CORROSION AND CHECKED LIMIT. REMOVED CORROSION FROM FLOOR BOARD FLANGE AND CORRODED PREVIOUS REPAIR AS REQUIRED. IAW SRM 51-70-40 REMAINING MATERIAL IS OUT OF LIMITS REF: SRM 51-10-10, TREATED, PRIMED IAW SRM 51-20-42/43. PAINTED. MATERIAL REMOVED IS ACCEPTABLE IAW SAAB DOCUMENT 340SDS000376.