What was found
FOUND DURING C-CHECK, CORROSION ON FLOOR BOARD FLANGE AT BLO.0 FROM STA 294.0 TO STA 363. REFER TO CELSIUS W/O 18955, TASK CARD 1546, AND SAAB STATEMENT 340SDS000376. MAINTENANCE REMOVED CORROSION AND CHECKED LIMIT. REMOVED CORROSION AS REQUIRED IAW SRM 51-70-40. REMAINING MATERIAL IS OUT OF LIMITS REF SRM 51-10-10 TREATED AND PRIMED IAW SRM 51-20-42/43 PAINTED SRM 51-20-43.MATERIAL REMOVED IS ACCEPTABLE IAW SAAB DOCUMENT 340SDS000376.