What was found
FOUND DURING C-CHECK, SEVERAL DENTS AFT OF RT ICE SHIELD AT FUSELAGE STA 339.0 TO STA 363.0 REFER TO CELSIUS W/O 19007, TASK CARD 2523, AND SAAB STATEMENT 340SDS000435. MAINTENANCE FOUND DENTS OUT OF ALLOWABLE LIMIT DISTANCE BETWEEN DENTS LESS THAN 4X L IAW SAAB SRM 51-10-10. FABRICATED REPAIR DOUBLER/TRIPLER PER PRINCIPLES OF SRM 53-70-10. ALODINED, PRIMED AND TOPCOATED PER SRM 51-20-42/43, INSTALLED DOUBLER AND TRIPLER REF SAAB SRM 53-70-10. REMAINING DENTS ARE ACCEPTED AS IS IAW SAAB STAEMENT 340SDS000435.