FOUND DURING C-CHECK, SEVERAL DENTS AFT OF LT ICE SHEILD AT FUSELAGE STA 350.0 REFER TO CELSIUS W/O 19007, TASK CARD 2530, AND SAAB STATEMENT 340SDS000435. MAINTENANCE CHECKED LIMIT, FOUND DENTS OUT OF ALLOWABLE LIMIT, DISTANCE BETWEEN DENTS LESS THAN 4XL IAW SAAB SRM 51-10-10. NO CRACKS NOTED IAW FFVNDT006. DENTS ARE ACCEPTED AS IS, NO FURTHER ACTION NECESSARY IAW SAAB STAEMENT 340SDS000435.