What was found
FOUND DURING C-CHECK, CORROSION ON CENTER AISLE FLOORBOARD ANGLES FROM STA 294-339. REFER TO CELSIUS TASK CARD 1539, W/O19007. MAINTENANCE REMOVED CORROSION FROM AFFECTED AREA , SRM 51-10-10 FOUND OUT OF LIMITS IAW 51-70-4, FABRICATED 2 EA. ANGLES PER SAMPLE IAW SRM 51-20-20, 51 -20-30. TREATED, PRIMED AND TOPCOATED ANGLE , AND INSTALLED 2 EA. ANGLES PER PRI NCIPLES OF SRM 51-40-21/23.