What was found
FOUND DURING C-CHECK, SEVERAL DENTS ON RT FUSELAGE BEHIND THE ICE SHELD AT APPROX. STA 350 AND SL 1634. REFER TO CELSIUS TASK CARD 2522, W/O 19036. MAINTENANCE FOUND DENTS OUT OF ALLOWABLE LIMIT REF SAAB SRM 51-10-10 LESS THAN 4 XL AND 51-10-10 DENT TYPE 1 AREA 2, NDTPERFFVNDT006EC. NO CRACKS NOTED. MAINTENANCE REPAIRED DENTS, FOR CORRECTIVED ACTION AND DETAIL SEE IPM 12 FORM. REPAIR COVERED AREA DAMAGE DISCREPANY FROM W/O 19036, TASK 2523.