SDR MALA000755

Service difficulty report · Smoke Detector · Saab 340B

Difficulty date
December 12, 2000
Submitted
December 28, 2000
Operation
Air carrier
Aircraft
N422XJ
Make and model
Saab 340B
Aircraft serial
422
Part
Smoke Detector
Condition
Malfunctioned
Location
E&E Bay
Stage of operation
TO
How discovered
O
Nature of condition
N
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

TAKE OFF ABORTED DUE TO AVIONICS SMOKE CAUTION COMING ON. AVIONICS SMOKE WENT OUT AFTER TWO SECONDS. MAINTENANCE DEFERRED AVIONIC SMOKE DETECTION SYSTEM PER MEL 26-13-3(B). FROM DMR AVIONIC SMOKE CAUTION LIGHT CAME ON AFTER TO. MAINTENANCE REPLACED AVIONICS SMOKE DETECTOR IAW MM. OPS CHECK GOOD. REINSTALLED AVIONICS RACK DOOR AS REQUIRED. ALL CHECKS GOOD. REMOVED FROM DMR, MXC NOTIFIED.