What was found
FOUND DURING C-CHECK, CORROSION ON FLOOR SUPPORT ANGLE AT STA 225. REFER TO CELSOIS W/O 19279, TASK 1540. MAINTENANCE REMOVED CORROSION IAW SRM 51--70-40. MATERIAL IS OUT OF LIMITS REF: SRM 51-10-10. FABRICATED NEW ANGLE IAW SRM 51-20-20/51-40-60, ALODINED, PRIMED AND PAINTED IAW SRM 51-20-42/43. INSTALLED IAW SRM 51-40-21.