What was found
FOUND DURING C-CHECK, CORROSION ON UPPER ANGLE OF FRAME AT STA 258 BENEATH FLOOR. REFER TO CELSIUS W/O 19279, TASK 1542. MAINTENANCE REMOVED CORROSION IAW SRM 51-70-40. MATERIAL IS OUT OF LIMITS REF: SRM 51-10-10. FABRICATED NEW ANGLE IAW SRM 51-20-20/30, 51-40-60, ALODINED, PRIMED AND PAINTED IAW SRM 51-20-42/43. INSTALLED IAW SRM 51-40-21.