What was found
FOUND DURING C-CHECK, CORROSION ON UPPER ANGLES AT INTERCOASTAL BETWEEN FRAMES AT STA 236 AND STA 238, BENEATH FLOOR AT LBL 10. REFER TO CELSIUS W/O 19279, TASK 1541. MAINTENANCE REMOVED CORROSION IAW SRM 51-70-40. MATERIAL IS OUT OF LIMITS REF: 51-10-10, FABRICATED REPAIR ANGLE IAW SRM 51-20-20/51-40-60, ALODINED, PRIMED AND PAINTED IAW SRM 51-20-42/43. INSTALLED REPAIR ANGLES IAW SRM 51-40-21.