What was found
FOUND DURING C-CHECK, CORROSION ON UPPER ANGLE OF FRAME STA 236.5. REFER TO CELSIUS W/O 19317, TASK 1510. MAINTENANCE REMOVED CORROSION, OUT OF LIMITS ON UPPER ANGLE FRAME 236.5. FABRICATED NEW ANGLE IAW SRM 51-40-21, 51-20-30. ALODINE AND PRIMED PARTS IAW SRM 51-20-42/43. APPLIED TOPCOAT AND INSTALLED WET SEAL IAW SRM 51-20-41.