What was found
FOUND DURING C-CHECK, RT FUSELAGE HAS SEVERAL DENTS BETWEEN STA 339 THRU STA 363, AND SL1618 THRU SL1622. REFER TO CELSIUS W/O 19347, TASK 2518, AND SAAB EO STATEMENT 340SDS001021. MAINTENANCE CHECK LIMITS, FOUND TO BE OUT OF ALLOWABLE LIMIT REF SAAB SRM 51-10-10. PERFORM NDT: EC AND BOND TEST. NDT PER FFV. NDT006 & 004 EC & UT NO CRACKS, NO DISBONDS, DENTS ARE ACCEPTED AS IS REF SAAB ENGINEERING STATEMENT 340SDS001021.