What was found
FOUND DURING C-CHECK FROM, IN NASHVILLE, TN. FLOORBOARD FLANGE AT STA 231.0 HAS CORROSION. REFER TO W/O 19430, TASK 2543. MAINTENANCE BLENDED OUT CORROSION IAW SRM 51-70-40. REMAINING MATERIAL OUT OF LIMITS, REMOVED SEVERAL CORRODED RIVETS, ALODINED BARE METAL, FABRICATED REPAIR ANGLE FROM 2024T3, ALODINED, PRIMED AND TOPCOATEDREPAIR AND FLANGE, INSTALLED NEW RIVETS AND REPAIR ANGLE.