What was found
DURING 4K-CHECK IN CWA, FWD RT FUSELAGE RUDDER CIRCUIT AFT SINGLE CABLE IS CHAFFED. MAINTENANCE INSTALLED SERVICEABLE RT SINGLE AFT RUDDER CABLE PN 7227105-582 IAW SF340 AMM 27-21-25.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 4K-CHECK IN CWA, FWD RT FUSELAGE RUDDER CIRCUIT AFT SINGLE CABLE IS CHAFFED. MAINTENANCE INSTALLED SERVICEABLE RT SINGLE AFT RUDDER CABLE PN 7227105-582 IAW SF340 AMM 27-21-25.