What was found
DURING 4K-CHECK IN CWA, FOUND LT I/B FWD FUSELAGE RUDDER CIRCUIT 1 CABLE CHAFFED. MAINTENANCE REMOVED AND REPLACED LT I/B FWD FUSELAGE RUDDER PN 7227105-571 CIRCUIT 1 CABLE IAW SF3 AMM 27-21-25.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 4K-CHECK IN CWA, FOUND LT I/B FWD FUSELAGE RUDDER CIRCUIT 1 CABLE CHAFFED. MAINTENANCE REMOVED AND REPLACED LT I/B FWD FUSELAGE RUDDER PN 7227105-571 CIRCUIT 1 CABLE IAW SF3 AMM 27-21-25.