SDR MALA020423

Service difficulty report · Valve · Bac AVRO146RJ85A

Difficulty date
July 18, 2002
Submitted
July 22, 2002
Operation
Air carrier
Aircraft
N517XJ
Make and model
Bac AVRO146RJ85A
Aircraft serial
E2335
Part
Valve
Part number
3502B000004
Condition
Failed
Location
Nr 2 A/C Pack
Stage of operation
TX
How discovered
O
Nature of condition
J
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING FLIGHT 3483, PACK NR 2 HI TEMP LIGHT ILLUMINATED PACK NR 2 DUCT TEMP AT 100 DEGREES. GATE RETURN. MAINTENANCE REMOVED AND REPLACED 31 PAC COUPLING ALSO REMOVED AND REPLACED NR 2 PAC VALVE PN 3502B000-004 SN/OFF 1086 SN/ON 1069. IAW AVRO AMM 21-10-11-401. SEE MM 409 086167 FOR DETAILS ALL CHECKS GOOD.