SDR MALA030346

Service difficulty report · Ptu · Bac AVRO146RJ85A

Difficulty date
July 23, 2003
Submitted
July 29, 2003
Operation
Air carrier
Aircraft
N507XJ
Make and model
Bac AVRO146RJ85A
Aircraft serial
E2316
Part
Ptu
Part number
4204002
Part serial
OFFOH75
Condition
Malfunctioned
Location
Hyd System
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING FLIGHT NR 3482, NR 3 ENGINE HYDRAULIC TEMP LIGHT CAME ON. FOLLOWED QRH AND MX PROCEDURES, AFTER COOLING AND APX 50 MILES OUT FROM LANDING TURNED PUMP BACK UNDER DIRECTION OF MXC-DID NOT ILLUMINATE. AIR RETURN TO MEM. MAINTENANCE REPLACED PTU IAW AMM 29-20-17 PN 4204002 SN/ON LW85, SN/OFF OH75 AND REPLACED AIRBRAKE SERVO VALVE AS A PRECAUTIONARY MEASURE IAW AMM 27-63-14, PN P458A0101-02 SN/ON DAW 51-98 SN/OFF DAW49-98 RAN GREEN SYSTEM HYDRUALIC NO HIGH TEMP INDICATION NOTED.SEE 409 NR 181762 AND CONTINUATION NR 040003,040004,040000,039971 AND 039693 FOR FURTHER DETAIL.