What was found
DURING 4Y/2Y INSPECTION IN CWA, FRAME 258 TOP PROFILE HAS CORROSION. MAINTENANCE CUT OUT DAMAGE, FABRICATED REPAIR, INSTALLED NEW FWD ANGLE IAW SRM 51 AND EO NR 53102. REF LOG PAGE NR 195722 FOR DETAIL. A/C RELEASE DATE 10/12/2003.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 4Y/2Y INSPECTION IN CWA, FRAME 258 TOP PROFILE HAS CORROSION. MAINTENANCE CUT OUT DAMAGE, FABRICATED REPAIR, INSTALLED NEW FWD ANGLE IAW SRM 51 AND EO NR 53102. REF LOG PAGE NR 195722 FOR DETAIL. A/C RELEASE DATE 10/12/2003.