SDR MALA030523

Service difficulty report · Control Module · Saab 340B

Difficulty date
December 7, 2003
Submitted
December 9, 2003
Operation
Air carrier
Aircraft
N433XJ
Make and model
Saab 340B
Aircraft serial
340B433
Part
Control Module
Part number
44730501
Part serial
L258945
Condition
Malfunctioned
Location
Deice System
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING FLIGHT 3177 RIGHT INTAKE HEAT MSTER CAUTION COME ON WITH THE RIGHT ENGINE ANTI-ICE SELECTED ON AFTER RESETTING THE SWITCH THE CAUTION LIGHT COMES BACK ON AFTER A FEW MINUTES. AIR RETURN TO MSP. MAINTENANCE REMOVED AND REPLACED RIGHT INTAKE HEAT DEICE CONTROL MODULE P/N 44730-501, S/N OFF L258945, S/N ON L248464. OPS CHECK GOOD.

More about the Saab 340B