SDR MALA040585

Service difficulty report · Ptu · Bac AVRO146RJ85A

Difficulty date
September 23, 2004
Submitted
September 30, 2004
Operation
Air carrier
Aircraft
N524XJ
Make and model
Bac AVRO146RJ85A
Aircraft serial
E2349
Aircraft time
11,179 hours, 10,947 cycles
Part
Ptu
Condition
Overheated
Location
Hyd System
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

APPROX 25 MIN INTO FLIGHT AT ALT 29000 THE GREEN SYSTEM HIGH TEMP CAUTION LIGHT ILLUMINATED. COMPLETED QRH AND SHUT GREEN SYSTEM OFF. HIGH TEMP LIGHT WENT OFF ABOUT A MINUTE LATER. MAINTENANCE INSPECTED HYD SYSTEM, NO LEAKS NOTED. PERFORMED DECAY TEST, OK. NOTED PTU OVERTEMPING PRESSURE CYCLING ERRATICLY. REPLACED PTU IAW 29-20-17, FAULT ISOLATION 29-30-00 FIGURE 111. TEST FLIGHT SATISFACTORY. COMPLETED POST FLIGHT WALKAROUND, NO DISC NOTED AT THIS TIME.