SDR MALA040771

Service difficulty report · Control Switch · Bac AVRO146RJ85A

Difficulty date
December 6, 2004
Submitted
December 13, 2004
Operation
Air carrier
Aircraft
N505XJ
Make and model
Bac AVRO146RJ85A
Aircraft serial
E2313
Aircraft time
14,963 hours, 14,493 cycles
Part
Control Switch
Condition
Damaged
Location
Outflow Valve
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW STATED OUTFLOW VALVE WOULD NOT CLOSE. AIR RETURN TO MSP. MAINTENANCE FOUND OUTFLOW VALVE MODE SWITCH OUT OF DETENTS. REPOSITIONED SWITCH AS REQUIRED, PERFORMED CONTROLLER SELF TEST, ALL CHECKED GOOD. PERFORMED CONTROLLER FUNCTIONAL TEST AMM 21-30-00 501, ALL CHECKED GOOD.