What was found
NR 3 RT INNER FUEL PUMP LOW PRESS ILLUMINATED. REMOVED AND REPLACED C/B B11 P/N S2653-005. REMOVED AND REPLACED RELAY 3QG4, PERFORMED VOLT CHECKS ON BUSS TIE CONTACTS. CHECKS GOOD. RAN AC AT DIFFERENT POWER SETTINGS. NO FAULTS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 3 RT INNER FUEL PUMP LOW PRESS ILLUMINATED. REMOVED AND REPLACED C/B B11 P/N S2653-005. REMOVED AND REPLACED RELAY 3QG4, PERFORMED VOLT CHECKS ON BUSS TIE CONTACTS. CHECKS GOOD. RAN AC AT DIFFERENT POWER SETTINGS. NO FAULTS.