What was found
DURING 4K CHECK IN BNA FOUND FLOOR FLANGE NUT PLATE ATTACH POINTS ARE CORRODED OUT OF LIMITS AT PAX DOOR THRESHOLD. BRACKETS HAVE BEEN REMOVED AND REPLACED IAW SRM 51-40-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 4K CHECK IN BNA FOUND FLOOR FLANGE NUT PLATE ATTACH POINTS ARE CORRODED OUT OF LIMITS AT PAX DOOR THRESHOLD. BRACKETS HAVE BEEN REMOVED AND REPLACED IAW SRM 51-40-21.