SDR MALA050434

Service difficulty report · Sensor · Saab 340B

Difficulty date
May 22, 2005
Submitted
May 26, 2005
Operation
Air carrier
Aircraft
N442XJ
Make and model
Saab 340B
Aircraft serial
340B442
Aircraft time
16,225 hours, 17,638 cycles
Part
Sensor
Part number
QR50V
Condition
Failed
Location
Pitot Heat
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LT PITOT HEAT FAILED EN ROUTE TO TVC. RAN QRH PROBLEM REMAINED AFTER RESETTING CB. CB WAS NOT TRIPPED. DIVERTED TO CWA. REMOVED AND REPLACED LT PITOT HEAT AC CURRENT SENSOR, PN QR5OV PER SAAB AMM 30-32-05-2. OPS CHECK GOOD.

More about the Saab 340B