SDR MALA050654

Service difficulty report · Valve · Bac AVRO146RJ85A

Difficulty date
August 15, 2005
Submitted
August 23, 2005
Operation
Air carrier
Aircraft
N526XJ
Make and model
Bac AVRO146RJ85A
Aircraft serial
E2351
Aircraft time
12,746 hours, 12,355 cycles
Part
Valve
Part number
711493
Part serial
G014330
Condition
Failed
Location
Mlg
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LOSS OF GREEN HYD SYSTEM. RAN CHECK LIST AND PERFORMED EMERGENCY GEAR EXTENSION. REPLACED GREEN SYSTEM HYD SELECTOR VALVE NR 3 ENGINE HYD PUMP AND FLUSHED GREEN SYSTEM HYD SYSTEM AND REPLACED FILTERS. REMOVED AND REPLACED SELECTOR 71149-3 SN ON/OFF F9748464 IAW 24-23-31A-D. LEAK AND OPS CHECK GOOD OF SELECTOR VALVE. INSTALLED NEW ENGINE DRIVEN PUMP PN 521449 SN ON MX618453 IAW 29-10. BLED L AND R OVERCENTER JACKS. FLUSHED HYD LINES FROM HYD BAY TO NR 3 EDP. LEAK CHECKS GOOD. REMOVED AND REPLACED NR 3 ENGINE ISOLATION VALVE PN HTE9531-3, SN OFF 190VB115 ON 190VB147IWA AMM 29-10-14. LEAK AND OPS CHECKS GOOD NR 3 ENGINE HYD PUMP. OP AND LEAK CHECK GOOD.