What was found
DENT ON RIGHT AFT FUSELAGE AT STA 719, 12 INCHES DOWN AND 24 INCHES FORWARD OF RIGHT HAND HORIZONTAL STABILIZER. REPAIRED AS PER ENGINEERING ORDER S53040 PATCH 8.5 INCHES X 19.5 INCHES FABRICATED WITH 2024 T3 .063 THICK INSTALLED BETWEEN STA 718.0 AND 725.5, BETWEEN STRINGER SL1508 AND SL1514 WITH SOLID RIVETS.