What was found
DURING 4K INSPECTION IN YQB FOUND THE RT INTAKE DUCT WAS CHAFING ON THE NACELLE FRAME AT STATION 197. THE REPAIR WILL BE CARRIED OUT IAW MESABA EOS54147 ON MM409263256.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 4K INSPECTION IN YQB FOUND THE RT INTAKE DUCT WAS CHAFING ON THE NACELLE FRAME AT STATION 197. THE REPAIR WILL BE CARRIED OUT IAW MESABA EOS54147 ON MM409263256.