SDR MALA060148

Service difficulty report · Outflow Valve · Bac AVRO146RJ85A

Difficulty date
March 11, 2006
Submitted
March 15, 2006
Operation
Air carrier
Aircraft
N513XJ
Make and model
Bac AVRO146RJ85A
Aircraft serial
E2329
Aircraft time
15,826 hours, 15,146 cycles
Part
Outflow Valve
Condition
Failed
Location
Cabin Pressure
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found